Skip to content

AlertManager

The AlertManager provides a centralized way to create and manage Driver Station alerts. It wraps WPILib's frc::Alert system and adds support for auto-checked alerts that monitor logged values.

Overview

AlertManager supports two types of alerts:

  • Manual alerts - Turned on/off directly by your code
  • Auto-checked alerts - Automatically trigger based on logged values
graph LR
    A[Your Code] -->|Manual| B[AlertManager]
    C[LogTable] -->|Auto-check| B
    B --> E[Elastic or similar driver dashboard]

Manual Alerts

Manual alerts are the simplest form - you control when they appear and disappear.

auto& alerts = tkit::AlertManager::GetInstance();

// Show alerts
alerts.Info("calibration", "Gyro calibrating...");
alerts.Warning("battery", "Battery below 11V");
alerts.Error("motor", "Motor 3 not responding");

// Clear an alert (pass false)
alerts.Warning("battery", "Battery below 11V", false);

// Or remove it completely
alerts.ClearManualAlert("battery");

Each alert is identified by a unique key. If you call the same key twice, it updates the existing alert rather than creating a new one.

Alert Types

Method Severity Use For
Info() Low Status updates, calibration progress
Warning() Medium Degraded performance, approaching limits
Error() High Failures, safety-critical issues

Auto-Checked Alerts

Auto-checked alerts monitor values in your LogTable and trigger automatically when conditions are met. They are evaluated automatically during Logger::Periodic().

Threshold Alerts

Trigger when a value goes above or below a threshold:

auto& alerts = tkit::AlertManager::GetInstance();

// Alert when battery drops below 11V
alerts.AddThresholdAlert(
    "Power/BatteryVoltage",           // Log key to monitor
    "Low battery voltage!",            // Alert message
    11.0,                              // Threshold
    tkit::AlertCondition::kBelow,     // Trigger when below
    frc::Alert::AlertType::kWarning   // Severity (optional, defaults to Warning)
);

// Alert when motor temperature exceeds 80C
alerts.AddThresholdAlert(
    "DriveTrain/MotorTemp",
    "Motor overheating!",
    80.0,
    tkit::AlertCondition::kAbove,
    frc::Alert::AlertType::kError
);

Range Alerts

Trigger when a value leaves an allowed range:

// Alert if arm angle is outside safe operating range
alerts.AddRangeAlert(
    "Arm/Angle",
    "Arm angle out of safe range!",
    -45.0,   // Min allowed
    90.0,    // Max allowed
    frc::Alert::AlertType::kWarning
);

Change Alerts

Trigger when a value differs from an expected value:

// Alert if drive mode changes unexpectedly
alerts.AddOnChangeAlert(
    "DriveTrain/Mode",
    "Drive mode changed!",
    0.0,  // Expected value (0 = normal mode)
    frc::Alert::AlertType::kInfo
);

// Works with booleans too
alerts.AddOnChangeAlert(
    "Intake/BeamBreak",
    "Game piece detected",
    false,  // Expected state
    frc::Alert::AlertType::kInfo
);

Clearing Alerts

auto& alerts = tkit::AlertManager::GetInstance();

// Clear a specific manual alert
alerts.ClearManualAlert("battery");

// Clear auto-checked alerts for a log key
alerts.ClearAutoAlert("Power/BatteryVoltage");

// Clear all manual alerts
alerts.ClearAllManualAlerts();

// Clear all auto-checked alerts
alerts.ClearAllAutoAlerts();

// Clear everything
alerts.Clear();

Supported Value Types

Auto-checked alerts work with these logged value types:

LogType Behavior
double Threshold and change alerts
float Threshold and change alerts
int64 Threshold and change alerts
bool Change alerts (use boolean overload)
string Change alerts (equality comparison)
arrays Change alerts (element-wise comparison)

Unsupported Types